class PWM – pulse width modulation

This class provides pulse width modulation output.

Example usage:

from machine import PWM

pwm = PWM(pin)          # create a PWM object on a pin
pwm.duty_u16(32768)     # set duty to 50%

# reinitialise with a period of 200us, duty of 5us
pwm.init(freq=5000, duty_ns=5000)

pwm.duty_ns(3000)       # set pulse width to 3us

pwm.deinit()

Constructors

class machine.PWM(dest, \*, freq, duty_u16, duty_ns)

Construct and return a new PWM object using the following parameters:

  • dest is the entity on which the PWM is output, which is usually a machine.Pin object, but a port may allow other values, like integers.

  • freq should be an integer which sets the frequency in Hz for the PWM cycle.

  • duty_u16 sets the duty cycle as a ratio duty_u16 / 65535.

  • duty_ns sets the pulse width in nanoseconds.

Setting freq may affect other PWM objects if the objects share the same underlying PWM generator (this is hardware specific). Only one of duty_u16 and duty_ns should be specified at a time.

Methods

PWM.init(\*, freq, duty_u16, duty_ns)

Modify settings for the PWM object. See the above constructor for details about the parameters.

PWM.deinit()

Disable the PWM output.

PWM.freq([value])

Get or set the current frequency of the PWM output.

With no arguments the frequency in Hz is returned.

With a single value argument the frequency is set to that value in Hz. The method may raise a ValueError if the frequency is outside the valid range.

PWM.duty_u16([value])

Get or set the current duty cycle of the PWM output, as an unsigned 16-bit value in the range 0 to 65535 inclusive.

With no arguments the duty cycle is returned.

With a single value argument the duty cycle is set to that value, measured as the ratio value / 65535.

PWM.duty_ns([value])

Get or set the current pulse width of the PWM output, as a value in nanoseconds.

With no arguments the pulse width in nanoseconds is returned.

With a single value argument the pulse width is set to that value.